Nitkellmu Dwar L-Applikazzjoni tal-Gauge tal-Pressjoni

Apr 09, 2022

introduzzjoni

Il-pressjoni hija waħda mill-parametri tal-proċess importanti fil-produzzjoni industrijali. Jekk il-pressjoni ma tissodisfax ir-rekwiżiti, mhux biss taffettwa l-effiċjenza tal-produzzjoni, tnaqqas il-kwalità tal-prodott, iżda saħansitra tikkawża inċidenti serji ta 'sikurezza. Allura l-kejl tal-pressjoni għandu status speċjali fil-produzzjoni industrijali. Dan l-artikolu jintroduċi l-għażla, l-installazzjoni u l-kalibrazzjoni tal-gauges tal-pressjoni rispettivament.

L-ewwel, l-għażla tal-gauge tal-pressjoni

L-għażla korretta tat-tip ta 'strument skont ir-rekwiżiti tal-proċess tal-prodott hija prerekwiżit importanti biex jiġi żgurat it-tħaddim normali tal-istrument u l-produzzjoni sikura. Ġeneralment, it-tliet rekwiżiti li ġejjin għandhom jiġu kkunsidrati meta tagħżel it-tip ta 'strument: (1) Agħżel skont ir-rekwiżiti tal-proċess tal-prodott fil-produzzjoni industrijali. Pereżempju, jekk humiex meħtieġa trasmissjoni remota, reġistrazzjoni awtomatika jew allarm; (2) Skont il-proprjetajiet fiżiċi u kimiċi tal-mezz imkejjel. Bħal korrużività, temperatura, viskożità, grad ta 'kontaminazzjoni, proprjetajiet li jaqbdu u splussivi, eċċ., Jekk tressaq rekwiżiti speċjali għall-istrument tal-kejl li jagħżel; (3) Skont il-kundizzjonijiet ambjentali fuq il--post. Bħal temperatura għolja, kamp elettromanjetiku, vibrazzjoni u -kondizzjonijiet ta 'installazzjoni fuq il-post, eċċ., jekk hemmx rekwiżiti speċjali għat-tip ta' strument, eċċ.

1. Determinazzjoni tal-medda tal-kejl tal-istrument

Sabiex tuża l-istrument b'mod raġonevoli u ekonomiku, il-firxa tal-istrument ma tistax tkun kbira wisq, iżda sabiex tiġi żgurata l-eżattezza tal-kejl, il-valur minimu tal-pressjoni mkejla ġeneralment mhuwiex inqas minn 1/3 tal-iskala sħiħa tal- strument. L-element elastiku huwa deformat b'mod permanenti minħabba stress eċċessiv għal żmien twil. Il-limitu ta 'fuq tal-gauge tal-pressjoni għandu jkun ogħla mill-valur massimu li għandu jitkejjel (1/21/3 tal-medda), u l-marġni għandu jkun riżervat.

2. Għażla tal-preċiżjoni tal-istrument

The accuracy of the instrument is determined according to the maximum measurement error allowed in the production process. It cannot be considered that the higher the accuracy of the instrument, the better. On the premise of meeting the process requirements, the instrument with lower precision, low price and durability should be selected as much as possible. Example of instrument type selection: The outlet pressure range of a compressor is 25~28MPa, and the absolute measurement error should not be greater than 1MPa. The process requires on-site observation and high and low limit alarms. Try to choose a pressure gauge correctly, and point out the model, accuracy and measurement range. The required conditions are: the measured pulsating pressure is 25~28MPa, and the absolute measurement error is less than or equal to 1MPa. Observation, high and low limit alarm. When selecting the instrument, consider that the pulsating pressure has a great influence on the life of the instrument, so the upper limit of the instrument selected is: P1=Pmax*2=28*2=56MPa. If the measurement range of the pressure gauge is 0~60MPa, then: 25MPa/60MPa>1/3, il-valur minimu tal-pressjoni mkejla mhuwiex inqas minn 1/3 tal-iskala sħiħa, u l-valur tal-limitu aktar baxx jissodisfa wkoll ir-rekwiżiti. Barra minn hekk, skont ir-rekwiżiti tal-iżball tal-kejl, jista 'jiġi kkalkulat li r-rekwiżiti għall-iżball permissibbli tal-istrument huma: 1/60100 fil-mija =1.67 fil-mija , sabiex l-istrument b'livell ta' preċiżjoni ta '1.5 jista' jissodisfaw ir-rekwiżiti ta 'żball.


It-2. Installazzjoni ta' gauge tal-pressjoni

Whether the pressure gauge is installed correctly or not directly affects the accuracy of the measurement results and the service life of the pressure gauge. The key to the installation of the pressure gauge is the selection of the pressure measuring point: (1) The pressure measuring point should be selected where the measured medium flows in a straight line. For the pipe segment, do not select it at the bend, bifurcation or dead end of the pipeline. (2) When measuring the liquid pressure, the pressure point should be perpendicular to the flow direction, the inner end face of the pressure pipe should be flush with the inner wall of the equipment, and there should be no protrusions or burrs. (3) When measuring the liquid pressure, the pressure-taking point should be at the lower part of the pipeline, so that no gas is accumulated in the pressure-guiding pipe; when measuring the gas pressure, the pressure-taking point should be above the pipe, so that no liquid is accumulated in the pressure-guiding pipe. (4) A shut-off  


It-3. Verifika u kalibrazzjoni ta' strumenti ta' skoperta ta' pressjoni (pressjoni differenzjali).

Qabel ma l-istrument jista 'jintuża, għandu jiġi vverifikat u kkalibrat. L-istrumenti użati għal żmien twil għandhom ukoll jiġu kkontrollati regolarment, u ċ-ċiklu għandu jiġi determinat skond il-frekwenza ta 'użu u l-grad ta' enfasi. Meta l-istrument ikollu sistema ta' trażmissjoni ta'-distanza twila u strument sekondarju, għandu jiġi vverifikat u kkalibrat flimkien mal-istrument sekondarju. Il-metodu tal-kalibrazzjoni tal-gauge tal-pressjoni huwa: uża gauge tal-pressjoni standard biex tikkalibra.


Ibgħat l-inkjesta